Buderus RC30 Provozní pokyny Strana 29

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 88
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 28
Basic functions 7
29
We reserve the right to make any changes due to technical modifications.
Operating instructions RC30 programmable room thermostat • Issue 02/2006
7.4.3 Activating thermal disinfection
If you activate the "Thermal disinfection" [pasteurisation] function,
the DHW is heated once a week or once a day to a temperature
which is high enough to destroy pathogenic agents (e.g.
legionella).
Press and hold down the "DHW" button.
Open flap.
Using the dial select "Yes". Then in accordance with the factory
settings thermal disinfection begins every Tuesday at 1.00 and
heats the water to 70 °C.
Release the "DHW" button. Thermal disinfection does not begin
immediately but on the specified day at the specified time (see
Chapter 9.7 "Thermal disinfection", page 69).
WARNING!
RISK OF SCALDING
from hot water at the taps.
During the thermal disinfection process the DHW can be heated
to a temperature above 60 °C.
z Only draw off mixed hot and cold water during or just after
thermal disinfection.
THERMAL
DISINFECTION
YES
Zobrazit stránku 28